MITSUBISHI SRK 50 ZS-S6 (1.5 TON) 4 STAR (Cooling+Heating)

90,000.00

ECO SMART – HYPER INVERTER ( R41OA ) – COOLING + HEATING Presenting India’s Highest Energy Saving (Cooling / Heating): 1.5 Ton Eco Smart Duty AC With R 410 A Refrigerant & Maximum 3.7* EER.

Compare
Categories: ,

Description

Specification ECO SMART – HYPER INVERTER ( R41OA ) – COOLING + HEATING
Model – Indoor Unit: SRK50ZS-S6
Model – Outdoor Unit:: SRC50ZS-S6
Maximum Tonnage** – (Cooling / Heating): 1.5
BEE STAR RATING – 2019: 5 Star
Compressor Type: Super Tropical – DC PAM Inverter – Return Cooled – Rotary
VFD – Variable Frequency Drive: Inverter Vector Control Technology for Higher Efficiency
Minimum Compressor RPM: 7 ~ 15 RPM – Using Vector Control Technology
Refrigerant Volume Control Using: Motorized Electronic Expansion Valve for Variable Refrigerant Flow
LCD Remote Control (iPM Controller): iPM ( Intelligent Power Module )
Power Source: 1 Phase, 220 / 230 V, 50 Hz
Maximum Cooling Capacity at** – 120% Load – BTU/hr: 18766
Rated Cooling Capacity at – 100% Load – BTU/hr: 17231
Rated Cooling Capacity at – 50% Load: 8615
Maximum Cooling Capacity at** – Watts: 5500
Rated Cooling Capacity at – 100% Load – Watts: 5050
Rated Cooling Capacity at – 50% Load – Watts: 2525
Rated Power Consumption at – 100% Load – Watts: 1375
Rated Power Consumption at – 50% Load – Watts:: 485
Rated EER / COP at – 100% Load – W/w: 3.7
Rated EER / COP at- 50% Load – W/w: 5.2
Rated Indian Seasonal Energy Efficiency by ISEER: 4.75
Current ( Minimum ~ Maximum )** – A: 1.30 ~ 6.5
Maximum Heating Capacity** – BTU/hr: 22519
Minimum Heating Capacity** – BTU/hr: 5459
Rated Heating Capacity** – BTU/hr: 19790
Maximum Heating Capacity** – Watts: 6600
Minimum Heating Capacity** – Watts: 1600
Rated Heating Capacity** – Watts: 5800
Maximum Power Consumption – Watts: 1550
Minimum Power Consumption – Watts: 250
Rated Power Consumption – Watts: 1300EER at Maximum Heating Capacity – W/w: 4.26
EER at Minimum Heating Capacity – W/w: 6.40
EER at Rated Heating Capacity – W/w:: 4.46
Current ( Heating mode ) – A: 1.0 ~ 6.0
Dimension (H x W x D) – Indoor Unit – mm: 290 x 870 x 230
Dimension (H x W x D) – Outdoor Unit – mm: 595 x 780(+62) x 290
Weight – Indoor Unit – Kgs: 12.5
Weight – Outdoor Unit – Kgs: 38
Cooling Coil Row – Indoor Unit – No.s: 3
Air Flow (CMH) – Indoor Unit – m3/hr: 1000
Long Reach Air Flow Upto – Indoor Unit – Meters: 6.09
Self Diagnosis Function – Indoor Unit: Yes
Sound Level (H/M/L) – Indoor Unit – dB: 45 / 36 / 28 / 22 (U-low)
Louver Swing – Indoor Unit: 3D + 3D AUTO
Special Filter – Indoor Unit: Allergen + Solar + Anti Bacterial – Filters
Blower Fan – Indoor Unit: Anti – Micro Bial Fan
DC Fan Motor Speed – Indoor Unit: Auto / Powerful / High / Medium / Low / ULo (Silent Mode) / Dry
Refrigerant Piping Thickness:18Gauge(1mm) – Liquid Line – mm: 6.35 ( 1/4″ )
Refrigerant Piping Thickness:18Gauge(1mm) – Gas Line – mm: 12.7 (1/2”)
Maximum (Pipe length / height Difference – Meters 15/10
Main Power Supply to – Outdoor Unit: 2.5 mm x 3 cores (including Earthing)
Connecting wiring – B/w IDU & ODU 2.5 mm x 4 cores (including Earthing)
perating – Temperature Range – Heating – °C: -15°C ~ 24°C
Area Coverage*** – Sq.Meters: 15.32 ~ 18.58